Dust Collector Not Working / Excessive Dust
Also covers: Powder contamination around the machine
Likely causes
- Collector switched off or poor electrical connection
- Collection bin full
- HEPA or cartridge filter clogged or damaged
- Suction hose blocked or leaking; build-up in ducting
- Vacuum motor failure
- Worn seals at the dosing or turntable area
- Powder unusually fine for the extraction setting
- Excess powder generation from machine adjustment
How to fix it
- 1Safety: stop the machine if dust is excessive, switch off the collector and wear a mask, gloves and safety glasses.
- 2Power: confirm the collector is on, check the emergency stop, supply and indicator lights.
- 3Empty the collection bin and dispose of powder to GMP procedures.
- 4Inspect the filter; clean using the filter cleaning system or replace. Never run without a filter.
- 5Check hoses and ducting for blockages, cracks and loose clamps; make connections airtight.
- 6Start the collector and confirm strong suction at each extraction point; listen for abnormal motor noise.
- 7If dust persists: check the separation and closing stations, dosing disc adjustment, powder scraper and seals, and reduce overflow.
It is fixed when
Strong suction at every point; no visible dust accumulation during production.
Stop it coming back
- Empty the bin and check the filter every batch.
- Inspect ducting during preventive maintenance.
Did this solve the problem?