Guide5.10
In-process checks
| Check | Frequency | Record |
|---|---|---|
| Count (hand count or checkweigher) | Start-up and every 30 minutes | IPC record |
| Desiccant present | Continuous; formal check every 30 minutes | IPC record |
| Cap torque (5 bottles) | Start-up and every 30–60 minutes | IPC record |
| Induction seal | Start-up, every 30 minutes, after stops, end | Seal monitoring record |
| Code and label | Start-up, every 30 minutes, at reel or ribbon changes | BPR |
| Metal detector challenge | Start-up, at set intervals, after stops, end | Monitoring record |
| Foil sensor challenge (no-foil cap) | Start-up, after stops or adjustments, end | IPC record |
| Cap height sensor challenge (loose cap) | Start-up, after bottle change or adjustment, end | IPC record |
| Bottle appearance | Continuous | BPR |