Problem & answerI-06
Water Tank Alarm / Low Water Level
Also covers: Cooling water refill
Likely causes
- Cooling water level low (evaporation or use)
- Poor circulation or blocked cooling line
- Cooling pump failure
- Leak at a hose or fitting
How to fix it
- 1When the sealer shows the low-water message, stop the induction sealer.
- 2Open the rear access door of the sealer to reach the cooling water tank.
- 3Open the tank lid and check the water level visible inside the tank.
- 4Fill with clean water only up to the correct level mark. Do not overfill: excess water overflows out of the tank.
- 5Close the tank lid and the rear door.
- 6Check hoses and fittings under the tank for leaks or kinks; clean the water filter if fitted.
- 7Reset the alarm, run the cooling system and confirm water is circulating.
- 8Seal-test 2–3 bottles before restarting production.
Technical note
The sealing head is water-cooled. Running without enough water overheats the head and stops sealing. Refill only after the low-water message or at the scheduled check, and always to the marked level.It is fixed when
Water at the correct level, circulating, and the alarm stays clear.
Stop it coming back
- Check the water level at every start-up; change the water on schedule.
- Wipe up any spilled water immediately; keep water away from electrical parts.