Problem & answerE-03
Dented or Pin-Holed Capsules
Likely causes
- Excessive pressure
- Misaligned closing station
- Damaged tooling or incorrectly sized / installed pins
- Overfilled capsules
- Moisture exposure
How to fix it
- 1Check closing pressure and alignment.
- 2Replace worn tooling or reinstall pins correctly.
- 3Reduce fill amount or move to a larger capsule size.
- 4Improve capsule storage to avoid moisture.
- 5Verify capsule quality.
It is fixed when
Capsules keep their correct shape with no pin holes.
Stop it coming back
- Check tooling alignment during preventive maintenance.
Did this solve the problem?