Problem & answerP-10
Missing or Wrong Labels
Likely causes
- Splice or missing label on reel
- Wrong label reel loaded
- Label verification not working
How to fix it
- 1Stop the line.
- 2Segregate suspect bottles.
- 3Verify the reel against the BPR (second person).
- 4Check the vision or verification system.
- 5Notify QA; reconcile labels.
Technical note
Labels carry allergen and dosage information. A wrong or missing label can cause serious harm, so label verification is treated as a critical control.It is fixed when
Correct label on every bottle; reconciliation balances.
Stop it coming back
- Remove all previous labels at line clearance.
Did this solve the problem?