Problem & answerA-08
Broken Capsules in the Feeder
Likely causes
- Poor capsule quality
- Excessive feeding pressure
- Damaged guide rails
- Incorrect machine adjustment
How to fix it
- 1Remove all broken capsules.
- 2Clean the feeder thoroughly.
- 3Check the guide rails for damage or burrs.
- 4Reduce feeding pressure if necessary.
- 5Use approved capsule shells only.
It is fixed when
No broken shells in the feeder after 100 capsules.
Stop it coming back
- Inspect incoming capsule shells before loading.
Did this solve the problem?