Problem & answerA-05
Capsule Magazine Blocked
Likely causes
- Broken capsules
- Capsules too large or deformed for the magazine
- Dust or debris in the magazine tracks
- Foreign material
- Worn magazine parts
How to fix it
- 1Stop the machine.
- 2Remove all capsules from the magazine.
- 3Confirm the capsules match the magazine size.
- 4Clean the magazine tracks completely. If debris is lodged, polish the track lightly with fine abrasive paper, then clean thoroughly.
- 5Inspect for wear or damage.
- 6Reload approved capsules and confirm smooth movement before restarting.
It is fixed when
Capsules travel smoothly through every magazine track.
Stop it coming back
- Clean the magazine at the end of every batch.
Did this solve the problem?