Problem & answerA-07
Double Capsule Feeding
Likely causes
- Incorrect feeder adjustment
- Worn feeding disc pockets
- Excessive vibration
- Poor capsule orientation
How to fix it
- 1Stop the machine.
- 2Adjust the feeding mechanism.
- 3Inspect the disc pockets; replace a worn feeding disc.
- 4Reduce vibration if excessive.
- 5Test with 100 capsules.
It is fixed when
One capsule per pocket across a 100-capsule test.
Stop it coming back
- Inspect feeding disc pockets during preventive maintenance.
Did this solve the problem?